Conductive Air Hose (SEH)
A reliable grounding can be achieved.
Specifications: Working temperature limit: Between -20℃ and + 60℃
Nominal designation | Inner diameter (mm) | Outer diameter (mm) | Regular size (m) | Maximum working pressure MPa at20℃ | Burst pressure MPa at 20℃ | Minimum bending radius (mm) | Weight (kg/m) | Regular size weight (kg) |
---|---|---|---|---|---|---|---|---|
SEH-6 | 6.5 | 10 | 100 | 1.5 | 7 | 35 | 0.057 | 5.7 |
SEH-8 | 8.5 | 12.5 | 100 | 1.5 | 7 | 45 | 0.084 | 8.4 |
Electric resistance value (Ω)
Nominal designation | Length of hose (m) 10m | Length of hose (m) 20m |
---|---|---|
SEH-6 | 1.0×105 | 2.0×105 |
SEH-8 | 1.0×105 | 1.5×105 |
*1. Purpose: The values of electric resistance of conductive air hoses, 6.5 x 1B x 10 and 8.5 x 1B x 12.5 in 10m and 20m, are measured.
*2. Test method: A joint (brass) is attached to the conductive air hoses, SE-H6 and SE-H8, and the electric resistance values between the hoses are measured.
*2. Test method: A joint (brass) is attached to the conductive air hoses, SE-H6 and SE-H8, and the electric resistance values between the hoses are measured.